The GC Methods/Retention Indices library has been extended by including summary statistical analysis of all data in the record. This information will be displayed in the spectrum text information even if the Retention Indices box is unchecked in the properties box. The summary data are given in terms of the type of column (standard non-polar(DB-1), semi-standard non-polar(DB-5), or polar(carbowax)), the median value of the retention data for that column type, the deviation and the number of experimental determinations. Note the deviation is calculated as the median absolute deviation. In the example below (for 6,6-Dimethyl-2-methylenebicyclo[3.1.1]heptan-3-ol or pinocarveol), there are 13 values for the DB5 series of data, 9 for the DB 1 and 12 for the polar column with median absolute deviaions of 4,7 and 8 respectively.

The data will also optionally be shown in the hit list, and the column that will be shown is user selectable.

The Retention Indices checkbox controls the display of  the detailed experimental data.  The number of GC Methods/Retention Indices displayed is controlled by selecting All or First and entering the number of values to be displayed. The default is to display the first two values. Displaying all values will cause the display to be slow if there are a very large number of literature values.

In addition, for many compounds, an Estimated Kovats Retention Index will be displayed based on the structure associated with the spectrum. These values are reported in index units (iu) with a confidence interval; e.g., “Confidence interval (Ketones): 57(50%) 246(95%) iu” reported for acetone. This means that there is a 50% probability the true value falls within 57 iu of the estimated value and 95% of the time the true value falls within 246 iu of the estimated value. The analysis is based on error measurements of all the data for the class of the compound given; i.e., in this example, ketones. These estimates only display if Retention Indices has been checked in the properties box. The estimates are not displayed in hit lists. If spectra in a user library have associated structures, an Estimated Kovats RI may also be listed for these spectra if the calculation is possible.

Important Information
Your purchase represents a single license for the use of the purchased library that is restricted to a single computer accessible by a single user at a time. There is no charge for backup or duplicate copies on a single computer accessible by a single user at a time. When you upgrade an existing license to a later version of the library, the previous version can continue to be used on the same single computer accessible by a single user at a time along with the upgraded version. However, you cannot remove the old version and install it on another computer.

1 - 2 of 2 items
Sort By:

 

All of these NIST products may be shipped as hard media or downloaded. Each copy is delivered with a discreet serial number, or in the case of multiple copy orders, in a range of serial numbers.